The Polatrak HP-1Z is a permanent reference electrode designed to allow positive monitoring and/or control of internal cathodic-protection systems for tanks and pressure vessels. It is one of the staple innovations of the TankGard system, and is not available on other tank cathodic-protection systems.
The HP-1Z E (extended) provides the electrode element on an extension wire inside the vessel. This makes it suitable for a number of applications where the electrode needs to be located in a specific area, or where internal access is limited to the upper areas of the tank or vessel. It is also ideal for monitoring tube-sheets in condensers or exchangers.
This instrument is rated to 3,000 psi, which makes it suitable for almost any vessel (access through either a 1/2" or 3/4" NPT fitting). The electrode may be wired to a monitoring station or simply read directly at the vessel using a regular multi-meter. The self-bleed zinc electrode provides a rugged +/- 20 mV electrode for just about any environment, and can be inserted through any fitting providing a ½" or ¾" NPT access.

Pressure rating |
3,000 psi |
|---|---|
| Reference electrode | Mil. spec zinc (auto-bleed) |
| Access required | ½”, ¾” or 1” NPT |
| Material | 316 SS |
| Design life | 10 Years |
| Temperature | 80ºC Maximum |