Raparound physical specifications
| Current rating |
20 - 50 amps for 20 Years, depending on water chemistry.
You can insert the table below as an additional guideline to specifiers. It can be linked to all ICCP products. |
| Frame |
1/2" steel ruggedized frame, hot dip galvanized.
Diver-friendly hinged attachment: 12" - 60" Diameter. HPile
or hex pile adapter available. Made from heavy gauge welded steel, hot dip galvanized to ASTM A123-M 09. Standard design includes ice-shearing cleats and anode-mount ice protection cap. Lifting padeyes and a hinged attachment allow safe and easy diver attachment. All fasteners are galvanized to ASTM A153 standards. |
| Shield |
Neoprene / PE Composite design; provides impact
resistance and dielectric strength. |
| Anode housing |
Black Delrin |
| Anode mounts |
Machined from Black Delrin, to provide protection against impact and abrasion. A total of 24 1/2" fasteners are used to ruggedly secure the active electrode array to the steel subframe.
|
| Di-Electric shield |
Main Dielectric is 3mm UPVC Sheet. Impact protectionis provided by 12 mm Neoprene outer shield. Shield provides equivalent 300 mm anode standoff distance from mounting pile.
|
| Anode element |
Mixed metal oxide (MMO) center connect
tube, 1" x 39" |
| Cable |
70 mm2 PE/PE/DGSWA/PE (typical), Various cable specifications available. All are double steel wire armored construction.
Ice-proof cable protection channels are availabe for areas with high icing tendency or wide tide variation. These may be provided in bolt-on or direct weld configuration.
|
MMO (Mixed Metal Oxide) Electrodes used in Deepwater products
|
|
|
Maximum current (amps) for 20 yr Life in: |
| Anode Type |
Dimensions |
Area sq.M |
Seawater |
Seabed silt |
Brackish water |
Fresh water |
| Tubular (Short) |
25mm x 1000 mm |
0.08 |
49.9 A |
8.0 A |
39.9 A |
16.0 A |
|
|
|
Maximum theoretical current (amps) for 20-year life in : |
| Product |
Anode type |
Quantity |
Seawater |
Seabed silt |
Brackish water |
Fresh water |
| Raparound |
Tubular short |
1 |
50 A |
N/A |
40 A |
16 A |
|
|
|
Deepwater rating (amps) 25 Yrs |
| Product |
Anode type |
Quantity |
Seawater |
Seabed silt |
Brackish |
Fresh |
| Raparound |
Tubular short |
1 |
40 |
N/A |
30 |
10 |
Deepwater recommends derating of anode performance as above to provide a high measure of system redundancy. The mixed metal oxides are a mixture of IrO2/Ta2O5. Titanium substrates meet ASTM B338 Grade 1 or 2 Standards. All connections are made as tubular denter-connects, helium tested (including discs).